{"product_id":"frick-transducer-913a0146h03","title":"Frick \/ Johnson Controls Pressure Transducer 913A0146H03","description":"\u003cp\u003e\u003cspan\u003e🔍 The Frick \/ Johnson Controls 913A0146H03 pressure transducer is engineered for precise pressure monitoring in industrial refrigeration and HVAC applications. Commonly used on Frick compressor packages and control panels, this transducer converts system pressure into a stable electrical signal for accurate control, safety interlocks, and performance monitoring. Built for harsh environments, it offers long-term stability, robust construction, and dependable operation in commercial plants, cold storage facilities, and process cooling systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e⚙️ Key features\u003c\/h4\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial-grade design:\u003c\/strong\u003e Built for continuous duty in refrigeration and HVAC systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStable output signal:\u003c\/strong\u003e Provides a linear DC output for integration with controllers and PLCs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRobust construction:\u003c\/strong\u003e Designed to withstand vibration, temperature swings, and demanding service conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact footprint:\u003c\/strong\u003e Fits easily into tight control panel or piping layouts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOEM replacement:\u003c\/strong\u003e Direct replacement for Frick \/ Johnson Controls OEM transducer part number 913A0146H03.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For exact pressure range, electrical ratings, and calibration details, refer to the original Frick \/ Johnson Controls documentation or system nameplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch4\u003e🧰 Typical applications\u003c\/h4\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrick industrial refrigeration compressor packages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAmmonia and other industrial refrigerant systems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChillers and process cooling systems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePackaged refrigeration units and cold storage plants\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePressure monitoring for safety shutdowns and alarms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e🔩 Mechanical \u0026amp; electrical (general characteristics)\u003c\/h4\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnection type:\u003c\/strong\u003e 1\/4\"-18 NPT external pressure port (typical for Frick transducers; verify on your unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePressure type:\u003c\/strong\u003e Absolute or gauge, depending on system design (check OEM documentation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical supply:\u003c\/strong\u003e Low-voltage DC supply (commonly in the 9–30 VDC range on similar Frick transducers)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal output:\u003c\/strong\u003e Analog DC output (commonly 1–5 VDC on similar models)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Threaded pressure port with electrical connector to control wiring harness\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Always confirm exact ratings and wiring requirements against your unit’s manual or nameplate before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch4\u003e🛠️ Installation \u0026amp; usage notes\u003c\/h4\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVerify compatibility:\u003c\/strong\u003e Match part number 913A0146H03 with your equipment’s service parts list or BOM.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDepressurize system:\u003c\/strong\u003e Ensure the system is safely depressurized and locked out before removing or installing the transducer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCheck wiring polarity:\u003c\/strong\u003e Confirm supply voltage and signal wiring per Frick \/ Johnson Controls schematics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalibrate \/ verify:\u003c\/strong\u003e After installation, verify readings against known system pressure or OEM test procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUse proper sealant:\u003c\/strong\u003e Apply appropriate thread sealant compatible with your refrigerant and system materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e📦 Condition \u0026amp; warranty (example text—adjust to your store policy)\u003c\/h4\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Surplus \/ liquidated inventory. Item may show minor shelf wear or handling marks but is unused.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e May ship in non-OEM packaging.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e Covered under Freeman Liquidators’ standard warranty policy. See store terms for details.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eCompatibility table\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv role=\"group\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003cstrong\u003eBrand \/ System\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003cstrong\u003eModel \/ Series\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrick Industrial Refrigeration\u003c\/th\u003e\n\u003ctd\u003eRSHC Compressor Packages\u003c\/td\u003e\n\u003ctd\u003eSuction \/ discharge pressure sensing\u003c\/td\u003e\n\u003ctd\u003eVerify part number in service parts list.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrick Vyper VSD Systems\u003c\/th\u003e\n\u003ctd\u003eVyper Variable Speed Drive (selected units)\u003c\/td\u003e\n\u003ctd\u003eControl \/ protection pressure input\u003c\/td\u003e\n\u003ctd\u003eCheck drive documentation for sensor specs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJohnson Controls Building Controls\u003c\/th\u003e\n\u003ctd\u003eP499 series-based control systems\u003c\/td\u003e\n\u003ctd\u003eGeneral pressure monitoring\u003c\/td\u003e\n\u003ctd\u003eConfirm electrical ratings and range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCustom OEM Panels\u003c\/th\u003e\n\u003ctd\u003eFrick \/ Johnson Controls control panels\u003c\/td\u003e\n\u003ctd\u003eAnalog pressure input to PLC \/ controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCross-reference table\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv role=\"group\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003cstrong\u003ePrimary Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003cstrong\u003eCross Reference \/ Related\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003cstrong\u003eDescription \/ Notes\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e913A0146H03\u003c\/th\u003e\n\u003ctd\u003eFrick \/ Johnson Controls OEM\u003c\/td\u003e\n\u003ctd\u003ePressure transducer for industrial refrigeration systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e913A0146H01\u003c\/th\u003e\n\u003ctd\u003eRelated Frick transducer\u003c\/td\u003e\n\u003ctd\u003eSimilar series; may differ in pressure range or configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e913A0146H04\u003c\/th\u003e\n\u003ctd\u003eP499CDJA501C\u003c\/td\u003e\n\u003ctd\u003e0–100 PSIA transducer, 1\/4\"-18 NPT, 9–30 VDC, 1–5 VDC output (example similar model).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eP499 series\u003c\/th\u003e\n\u003ctd\u003eJohnson Controls P499 family\u003c\/td\u003e\n\u003ctd\u003eFamily of pressure transducers used in HVAC \/ refrigeration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Freeman Liquidators","offers":[{"title":"Default Title","offer_id":49090698051803,"sku":"WALL NND10-1A","price":636.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0504\/9578\/3088\/files\/rn-image_picker_lib_temp_ff3ba45e-94b7-4999-8991-c16f9ea2f470.jpg?v=1786131280","url":"https:\/\/freemanliquidators.com\/products\/frick-transducer-913a0146h03","provider":"Freeman Liquidators","version":"1.0","type":"link"}