Frick / Johnson Controls Pressure Transducer 913A0146H03
Frick / Johnson Controls Pressure Transducer 913A0146H03 is backordered and will ship as soon as it is back in stock.
Pickup available at Wall
Usually ready in 24 hours
Description
Description
🔍 The Frick / Johnson Controls 913A0146H03 pressure transducer is engineered for precise pressure monitoring in industrial refrigeration and HVAC applications. Commonly used on Frick compressor packages and control panels, this transducer converts system pressure into a stable electrical signal for accurate control, safety interlocks, and performance monitoring. Built for harsh environments, it offers long-term stability, robust construction, and dependable operation in commercial plants, cold storage facilities, and process cooling systems.
⚙️ Key features
-
Industrial-grade design: Built for continuous duty in refrigeration and HVAC systems.
-
Stable output signal: Provides a linear DC output for integration with controllers and PLCs.
-
Robust construction: Designed to withstand vibration, temperature swings, and demanding service conditions.
-
Compact footprint: Fits easily into tight control panel or piping layouts.
-
OEM replacement: Direct replacement for Frick / Johnson Controls OEM transducer part number 913A0146H03.
Note: For exact pressure range, electrical ratings, and calibration details, refer to the original Frick / Johnson Controls documentation or system nameplate.
🧰 Typical applications
-
Frick industrial refrigeration compressor packages
-
Ammonia and other industrial refrigerant systems
-
Chillers and process cooling systems
-
Packaged refrigeration units and cold storage plants
-
Pressure monitoring for safety shutdowns and alarms
🔩 Mechanical & electrical (general characteristics)
-
Connection type: 1/4"-18 NPT external pressure port (typical for Frick transducers; verify on your unit)
-
Pressure type: Absolute or gauge, depending on system design (check OEM documentation)
-
Electrical supply: Low-voltage DC supply (commonly in the 9–30 VDC range on similar Frick transducers)
-
Signal output: Analog DC output (commonly 1–5 VDC on similar models)
-
Mounting: Threaded pressure port with electrical connector to control wiring harness
Important: Always confirm exact ratings and wiring requirements against your unit’s manual or nameplate before installation.
🛠️ Installation & usage notes
-
Verify compatibility: Match part number 913A0146H03 with your equipment’s service parts list or BOM.
-
Depressurize system: Ensure the system is safely depressurized and locked out before removing or installing the transducer.
-
Check wiring polarity: Confirm supply voltage and signal wiring per Frick / Johnson Controls schematics.
-
Calibrate / verify: After installation, verify readings against known system pressure or OEM test procedures.
-
Use proper sealant: Apply appropriate thread sealant compatible with your refrigerant and system materials.
📦 Condition & warranty (example text—adjust to your store policy)
-
Condition: Surplus / liquidated inventory. Item may show minor shelf wear or handling marks but is unused.
-
Packaging: May ship in non-OEM packaging.
-
Warranty: Covered under Freeman Liquidators’ standard warranty policy. See store terms for details.
Compatibility table
| Brand / System | Model / Series | Usage | Notes |
|---|---|---|---|
| Frick Industrial Refrigeration | RSHC Compressor Packages | Suction / discharge pressure sensing | Verify part number in service parts list. |
| Frick Vyper VSD Systems | Vyper Variable Speed Drive (selected units) | Control / protection pressure input | Check drive documentation for sensor specs. |
| Johnson Controls Building Controls | P499 series-based control systems | General pressure monitoring | Confirm electrical ratings and range. |
| Custom OEM Panels | Frick / Johnson Controls control panels | Analog pressure input to PLC / controller |
Cross-reference table
| Primary Part Number | Cross Reference / Related | Description / Notes |
|---|---|---|
| 913A0146H03 | Frick / Johnson Controls OEM | Pressure transducer for industrial refrigeration systems. |
| 913A0146H01 | Related Frick transducer | Similar series; may differ in pressure range or configuration. |
| 913A0146H04 | P499CDJA501C | 0–100 PSIA transducer, 1/4"-18 NPT, 9–30 VDC, 1–5 VDC output (example similar model). |
| P499 series | Johnson Controls P499 family | Family of pressure transducers used in HVAC / refrigeration. |
Disclosure Policy
Disclosure Policy
This product was acquired by Freeman Liquidators from a sale of merchandise subject to a commercial insurance loss. Freeman Liquidators is a secondary seller of products, is not affiliated with or sponsored by the manufacturer of the products and is not a manufacturer authorized seller of the products. Sale of this product by Freeman Liquidators is not subject to the policies of the manufacturer. Any warranty offered by the manufacturer is not available to you as the purchaser.
All products are NEVER USED but external packaging will have damage. Some items may be placed into other packaging to ensure safe shipping. All items are opened for inspection prior to shipment to ensure the best quality of products. Freeman Liquidators guarantees your satisfaction. If you are not completely satisfied with a purchased product, within 30 days from the date of purchase, return the product in its packaging and Freeman Liquidators will fully refund your money.
Delivery and Shipping
Delivery and Shipping
Shipping is automatically calculated at checkout.
In store pickup is sometimes the only option. These products are noted as such in our listings.
Some items have been set up so that they require a shipping quote. Please fill out the appropriate form on the product's page and we will respond within 24-48 hours with a freight quote.
What we ship is by best carrier, some products prepaid and others not, due to our large variances in product lines, physical sizes and weight.
At checkout you will be prompted for shipping alternatives dependent on these parameters. Products which fit standardized packaging may also have calculated shipping costs by weight and volume on our website.
In all cases our staff audits for the best shipping cost and if necessary will contact our customer with recommendations.
Freight/Palleted items that are not accepted by the recipient or are sent back to us due to undeliverable address may be refunded, but the return shipping fees will be deducted from the overall amount of refund.
All returned items are subject to a 10% handling fee.
Frick / Johnson Controls Pressure Transducer 913A0146H03 is backordered and will ship as soon as it is back in stock.
Frick / Johnson Controls Pressure Transducer 913A0146H03
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.